eArşiv@Adu

Psödoeksfoliyasyon sendromlu hastalarda Oküler Pulse Amplitüdü'nün dinamik kontur tonometre ile değerlendirilmesi

Basit öğe kaydını göster

dc.contributor.advisor Dayanır, Volkan
dc.contributor.author Işıklıgil, Işıl
dc.date.accessioned 2016-01-06T13:27:04Z
dc.date.available 2016-01-06T13:27:04Z
dc.date.issued 2009-01-01
dc.date.submitted 2009
dc.identifier.uri http://194.27.38.21/web/catalog/info.php?idx=32906154&idt=1
dc.identifier.uri http://hdl.handle.net/11607/882
dc.description.abstract İntraoküler basıncın sabit bir değeri yoktur. İntraoküler basınç değeri sistol sırasında en yüksek iken diastol sırasında en düşüktür. Bu çalışmanın amacı psödoeksfoliyasyon sendromlu hastalarda «ocular pulse amplitude» değerinin «pascal dynamic contour tonometry» kullanılarak değerlendirilmesidir. Metod: 32 psödoeksfoliyasyon sendromlu ve yaş ile cinsiyet uyumlu 32 normal hasta çalışmaya alındı. Tüm olgular «pascal dynamic contour tonometry» kullanılarak `ocular pulse amplitude' ölçülmesini de içeren tam bir oftalmolojik mueyeneden geçirildi. Bulgular: Hasta grupta aplanasyon tonometre ile ölçülen intraoküler basınç ortalaması 15,0±3,5 mmHg, pascal dinamik kontur tonometre ile ölçülen intraoküler basınç ortalaması 18,0±4,0 mmHg, OPA değeri ortalaması 2,60±0,92 mmHg olarak bulundu. Kontrol grubunda aplanasyon tonometre ile ölçülen intraoküler basınç ortalaması 15,0±3,7 mmHg , pascal dinamik kontur tonometre ile ölçülen intraoküler basınç ortalaması 17,0±3,0 mmHg , OPA değeri ortalaması 2,24±0,87 mmHg olarak tespit edildi. Bağımsız örneklerde t-testi yapılarak aplanasyon ile ölçülen intraoküler basınç (p=0,534), pascal dinamik kontur tonometre ile ölçülen intraoküler basınç (p=0,524) ve «ocular pulse amplitude» (p=0,085) değerleri arasında bir fark bulunmadı. Sağlıklı bireylerde OPA değerleri ile dinamik kontur tonometre ve aplanasyon tonometre kullanılarak ölçülen intraoküler basınç arasında istatistiksel olarak anlamlı pozitif korelasyon bulduk. Psödoeksfoliyasyon grubunda OPA değeri ile aplanasyon tonometre kullanılarak ölçülen intraoküler basınç arasında istatistiksel olarak anlamlı pozitif korelasyon varken dinamik kontur tonometre kullanılarak ölçülen intraoküler basınç arasında istatistiksel olarak anlamlı pozitif korelasyon yoktu. Sonuç: Ülkemizde sıkça görülen psödoeksfoliyasyon sendromlu olgulardaki, kan akımı ile intraokular basınç arasındaki ilişkiyi yansıtan «ocular pulse amplitude» değerini kontrol olguları ile karşılaştırdık. İstatistiksel olarak anlamlı bir fark tespit edemedik. tr_TR
dc.description.abstract Intraocular pressure (IOP) does not have a constant value. IOP is highest during systole and lowest during diastole. The aim of this study was to evaluate the ocular pulse amplitude in pseudoexfoliation syndrome using pascal dynamic contour tonometry. Methods: 32 patients with pseudoexfoliation syndrome and 32 age and sex matched controls were included into the study. All patients underwent complete ophthalmic examination including ocular pulse amplitude values determined by pascal dynamic contour tonometry. Results: In pseudoexfoliation syndrome group, mean intraocular pressure (IOP) with Goldmann was 15,0±3,5 mmHg, mean IOP with pascal dynamic contour tonometry (DCT) was 18,0±4,0 mmHg, mean OPA was 2,60±0,92 mmHg. In control group, mean intraocular pressure (IOP) with Goldmann was 15,0±3,7 mmHg, mean IOP with pascal dynamic contour tonometry (DCT) was 17,0±3,0 mmHg, mean OPA was 2,24±0,87 mmHg. There was no significant difference between groups with respect to intraocular pressure as measured with GAT (p=0,534), DCT (p=0,524), and OPA (p=0,085). We found a significant positive correlation between OPA and IOP values using DCT and GAT in healthy subjects. In the XFS group, there was a significant positive correlation between OPA and IOP values obtained by GAT but not IOP values obtained by DCT. Conclusion: Pseudoexfoliation is a common situation in our country. Ocular pulse amplitude that reflects association between blood pressure and IOP was compared with controls. There was no significant difference in the OPA values between healty and XFS tr_TR
dc.language.iso tur tr_TR
dc.publisher Adnan Menderes Üniversitesi, Tıp Fakültesi tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Ocular Pulse Amplitude tr_TR
dc.subject Psödoeksfoliyasyon Sendromu tr_TR
dc.subject Pascal Dinamik Kontur Tonometre tr_TR
dc.subject Goldmann Aplanasyon Tonometresi tr_TR
dc.subject Pseudoexfoliation Syndrome tr_TR
dc.subject Pascal Dynamic Contour Tonometer tr_TR
dc.subject Goldmann Applanation Tonometer tr_TR
dc.title Psödoeksfoliyasyon sendromlu hastalarda Oküler Pulse Amplitüdü'nün dinamik kontur tonometre ile değerlendirilmesi tr_TR
dc.title.alternative Evaluation of Ocular Pulse Amplitude by dynamic contour tonometry in patients with pseudoexfoliation syndrome tr_TR
dc.type Thesis tr_TR
dc.contributor.department Adnan Menderes Üniversitesi, Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı tr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster