eArşiv@Adu

Elektromanyetik alanın (50hz, 6mt) sıçan karaciğer ve böbreğine etkileri

Basit öğe kaydını göster

dc.contributor.author Erpek, Semra
dc.contributor.author Bilgin, Mehmet Dinçer
dc.contributor.author Doger, Füruzan Kaçar
dc.date.accessioned 2016-02-29T14:51:45Z
dc.date.available 2016-02-29T14:51:45Z
dc.date.issued 2007
dc.identifier.citation Erpek, S., Bilgin, M.D., Doger, F.Kaçar.(2008). Elektromanyetik alanın (50hz, 6mt) sıçan karaciğer ve böbreğine etkileri.Adnan Menderes Üniversitesi Tıp Fakültesi Dergisi,8(1),5-11. tr_TR
dc.identifier.issn 2149-9063
dc.identifier.uri http://meandrosmedicaljournal.org/article_9482/The-Effect-Of-Electromagnetic-Field-50-Hz-6mt-On-Rat-Liver-And-Kidney
dc.identifier.uri http://hdl.handle.net/11607/2171
dc.description.abstract Modern teknolojinin giderek ilerlemesinin bir sonucu olarak, bir çok endüstriyel ve evsel elektrikli aletlerin kullanımı ile birlikte, insanlar bunlardan kaynaklanan manyetik alanlara daha fazla maruz kalmaktadır. Son yıllarda elektromanyetik alan (EMA) olusturan aletlerin etkileri bir çok deneysel çalısmaya konu olmus ve farklı sonuçlara ulasılmıstır. Bu çalısmada elektromanyetik alana maruz kalan sıçanlarda karaciger ve böbrek dokusunun incelenmesi amaçlanmıstır. Bu çalısmada ortalama 290 gram agırlıgında 20 adet eriskin erkek Wistar albino sıçan kullanıldı. Deney hayvanları, her birinde 10'ar sıçan bulunacak sekilde “deney grubu ve kontrol grubu” olmak üzere iki gruba ayrıldı. Deney grubu günde 2 saat, haftada 7 gün olmak üzere 8 hafta süreyle 6 militesla (mT) (50 Hz, alternatif akım) EMA'a maruz bırakıldı. Deney sırasında sıçanların bulundugu ortamın sıcaklıgı termometre ile, manyetik alan ise Teslametre (Phyme) ile sürekli kontrol edildi. deney baslangıcında ve deney sonunda hayvanların canlı agırlıkları kaydedildi. Deney sonunda ötenazi uygulanan sıçanlardan doku örnekleri alındı. Formalin solusyonunda tespit edilen karaciger ve böbrek doku örnekleri rutin histolojik doku takibinden sonra parafine gömüldü. Parafin bloklardan alınan 5µ kalınlıgındaki kesitler Hematoksilen-Eosin, Periodik Asit Schiff ve Masson trikrom ile boyandı. Isık mikroskobunda histopatolojik olarak degerlendirilen kesitler dejenerasyon, fokal nekroz, fibrozis gibi histolojik bulgular yönünden semikantitatif olarak skorlandı. Elde edilen tüm sayısal veriler Mann-WhitneyUtesti ile istatistiksel olarak degerlendirildi. Deney hayvanlarının deney süresindeki agırlık artısı yüzdeleri ile karaciger ve böbrek agırlıkları açısından deney ve kontrol grubu arasında istatistiksel bir farklılık saptanmadı. Deney ve kontrol gruplarının toplam histolojik skorları arasında anlamlı bir farklılık olmadıgı belirlendi. Elde edilen bulgular, uzun süre 6 mT (50 Hz, alternatif akım) manyetik alana maruz kalan sıçanların karaciger ve böbrek dokusunda histolojik bir degisiklige neden olmadıgını göstermistir. tr_TR
dc.description.abstract In the last few decades, various investigations have been performed in order to determine the possible biological effects of electromagnetic fields (EMF) generated by power lines and telecommunication technologies. The long-term exposure toEMFmay have been linked to various disorders and may affect different organs. The aim of this study was to investigate the effect of 6 millitesla (mT)AC (alternate current) EMF on the rat liver and kidney. Twenty adult maleWistar rats were divided into 2 groups; one group was exposed to 50 Hz, 6 mTAC electromagnetic field for 8 weeks, 2 hours per day, and the other sham exposed, meaning that all other experimental conditions were the same except for EMF exposure. After 8 weeks, all subjects were sacrificed, livers and kidneys were removed and weighed. For histopathological examination, samples were fixed in 10% buffered formalin, embedded in paraffin, and then cut and stained with hematoxylin-eosin, PAS and Masson's trichrome. The histological samples were evaluated using the semi-quantitative scoring. Mann Whitney U test was applied for statistical analysis. For each animal the difference in body weight was calculated from the weight at the beginning of the experiment (day 0) and the weight at termination (day 56). The body weight gain of exposed group was less than that of the control group, but there was no significant difference between the two groups. The absolute and relative liver and kidney weights did not show any significant difference between the EMF exposed and sham exposed rats. Microscopic examination of liver and kidney samples revealed no significant differences between the EMF exposed and sham exposed rats. Present results show that whole body exposure to 50 Hz, 6 mT AC EMF doesn't cause gross and histological lesions on rat liver and kidney attributed to magnetic field exposure. tr_TR
dc.language.iso tur tr_TR
dc.publisher Adnan Menderes Üniversitesi Tıp Fakültesi Dergisi tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Elektromanyetik Alan tr_TR
dc.subject Karaciğer tr_TR
dc.subject Böbrek tr_TR
dc.subject Histoloji tr_TR
dc.subject Electromagnetic Field tr_TR
dc.subject Liver tr_TR
dc.subject Kidney tr_TR
dc.subject Histology tr_TR
dc.title Elektromanyetik alanın (50hz, 6mt) sıçan karaciğer ve böbreğine etkileri tr_TR
dc.title.alternative The effect of electromagnetic field (50 hz, 6mt) on rat liver and kidney tr_TR
dc.type article tr_TR
dc.relation.journal Adnan Menderes Üniversitesi Tıp Fakültesi Dergisi tr_TR
dc.contributor.authorID TR148666 tr_TR
dc.contributor.authorID TR2242 tr_TR
dc.contributor.department Adnan Menderes Üniversitesi Tıp Fakültesi, Histoloji Embriyoloji Anabilim Dalı tr_TR
dc.identifier.volume 1 tr_TR
dc.identifier.issue 8 tr_TR
dc.identifier.startpage 5 tr_TR
dc.identifier.endpage 11 tr_TR


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster