Prostat kanseri tedavisinde yoğunluk ayarlı radyoterapi planlamaları ile dozimetrik sistemlerden elde edilen doz dağılımlarının karşılaştırılması

Show simple item record

dc.contributor.advisor Gökçe, Melis
dc.contributor.author Koçyiğit, Deniz
dc.date.accessioned 2016-01-29T12:01:08Z
dc.date.available 2016-01-29T12:01:08Z
dc.date.issued 2015-01-01
dc.date.submitted 2015
dc.identifier.uri http://194.27.38.21/web/catalog/info.php?idx=52906898&idt=1
dc.identifier.uri http://hdl.handle.net/11607/1561
dc.description.abstract Prostat kanseri, diğer kanser türlerinde olduğu gibi vücuttaki normal hücre büyümesinin bozularak prostat bezinin kötü huylu büyümesi olarak bilinir. Tedavi yöntemlerinden biri olan ışınlama, eksternal (dış) radyoterapi ve brakiterapi olmak üzere iki şekilde yapılır. Prostat kanseri tedavisinde daha yüksek oranda tümör kontrolünü daha az yan etki ile sağlamak için yoğunluk ayarlı radyoterapi (YART) planlaması kullanılır. YART ile tedavi edilen hastaların bütün tedavi alanlarının tedaviden önce dozimetrik olarak hesaplanan doz dağılımı ile karşılaştırılarak kontrol edilmesi gerekir. Bu tez çalışmasında, YART planlamalarında hedef hacmin almış olduğu doz termolüminesans dozimetre (TLD), iyon odası ve 2D-ARRAY dedektör sistemi gibi dozimetrik sistemler kullanılarak ölçülüp karşılaştırılmıştır. Üç prostat kanseri hastası için, YART yöntemi ile oluşturulmuş tedavi planları, 2D-ARRAY ve TLD ölçümlerinin gerçekleştirildiği katı su fantomu üzerine aktarılmıştır. Her üç hasta için dozimetrik sistemlerden elde edilen sonuçlar YART ile karşılaştırılmıştır. 2D-ARRAY ile yapılan karşılaştırmada 3 mm DTA, %3 DD kriteri için γ değerlendirmesini geçen noktalar bulunmuştur. Karşılaştırmada γ değerlendirmesini geçen noktaların yüzdesine bakıldığında 2D-ARRAY ile yapılan ölçümlerin tedavi planlama sistemi ile uyumlu sonuçlar verdiği belirlenmiştir. Ġyon odası ile gerçekleştirilen nokta doz ölçümleri ve planlamalardan okunan dozlar arasındaki fark %3’den küçük bulunmuştur. TL dozimetreler ile ölçülen ve planlama sisteminden okunan doz değerleri arasındaki fark % 1–5 arasında bulunmuştur. Elde edilen sonuçlar ışığında dozimetrik sistemlerin avantaj ve dezavantajları kendi aralarında kıyaslanmıştır. tr_TR
dc.description.abstract As in other types of cancer, prostate cancer is the deterioration of normal cell growth in the body, known as malign enlargement of the prostate gland. Irradiation which is one of the treatment methods done in two ways as external radiotherapy and brachytherapy. In order to achieve high tumor control rate with minimum side effects Intensity Modulated Radiotherapy (IMRT) planning is used for prostate cancer treatment. Before treatment, all treatment fields in IMRT must be controlled and compared with dosimetrically obtained dose distribution. In this thesis, dose received by the target volume for IMRT plannings is measured and compared with the dosimetric systems such as thermoluminescent dosimeter (TLD), ionization chamber and 2D-array. For three prostate cancer patients, the treatment plans created with IMRT technique are transferred onto 2D-ARRAY and onto the solid water phantom which TLD studies are carried out. For the patients the results obtained from dosimetric systems are compared with those obtained from IMRT technique. For 2D-ARRAY measurements, the points that passed γ assessment for 3 mm DTA, %3 DD criteria have been found. According to the percentage of the points passed γ assessment, it is determined that 2D-ARRAY measurements have given consistent results with treatment planning system. The differences between point doses measured in ionization chamber and the doses read from planning system have been obtained less than %3. It is found that the difference between dose values of TLDs and planning system are in the range of 1-5%. According to the results the advantages and disadvantages of dosimetric systems are compared with each other. tr_TR
dc.language.iso tur tr_TR
dc.publisher Adnan Menderes Üniversitesi, Fen Bilimleri Enstitüsü tr_TR
dc.rights info:eu-repo/semantics/embargoedAccess tr_TR
dc.subject Yoğunluk Ayarlı Radyoterapi tr_TR
dc.subject Prostat Kanseri tr_TR
dc.subject İyon Odası tr_TR
dc.subject 2D-ARRAY Dedektör Sistemi tr_TR
dc.subject Termolüminesans Dozimetre tr_TR
dc.subject Intensity Modulated Radiotherapy tr_TR
dc.subject Prostate Cancer tr_TR
dc.subject Ionization Chamber tr_TR
dc.subject 2D-ARRAY Detector System tr_TR
dc.subject Thermoluminescent Dosimetry tr_TR
dc.title Prostat kanseri tedavisinde yoğunluk ayarlı radyoterapi planlamaları ile dozimetrik sistemlerden elde edilen doz dağılımlarının karşılaştırılması tr_TR
dc.title.alternative Comparison of the dose distribution obtained from dosimetric system with intensity modulated radiotherapy planning system in the treatment of prostate cancer tr_TR